1. Modular boiler houses operating with propane-butane mixture or natural gas provide maximum economic effect when used as a part of independent gas supply system.

Modular boiler houses as compared to permanent-set solutions has the following advantages:

  • Quick system preparation for putting into operation.
  • No need in permanent buildings and constructions
  • Possibility of boiler house capacity increase
  • Possibility of boiler house displacement

Modular boiler houses for propane-butane mixture (basic variant) are manufactured in the following capacity range (depending on complete set):

  • 100/130/160/200 kWt;
  • 250/300/500/750 kWt;
  • 1,0/1,5/2,0 MBt

Module boiler houses are made in two variants: “economy” and “business”. All components of “business” model (water heating boilers, water supply pumps, control sensors and so on) are doubled.
Boiler houses of 500 kWt capacity feature maximum economic efficiency. High level of boiler houses autonomy is ensured by propane-butane stock in a reservoir but also by use of diesel and gas electric generators, making a boiler house independent from external source of electric power.

 

Design features:

  • metal heat insulated containers ( dimension 20/40 ft);
  • easy detachable windows;
  • water heat boilers of mixed fuel (diesel fuel/propane-butane)
  • permanent-set automatically driven diesel/gas power station
  • automated in-feeding system (water treatment (softening), ready water storage reservoirs, pump with automated maintenance of a given pressure value);
  • multi-circuit model;
  • modern materials (including stainless steel alloy).
 

2. Single boiler plant specification

Specification of modular boiler houses 100-2000 kWt with single boiler
¹ Boiler house capacity Quont 200 kWt 300 kWt 500 kWt 750 kWt 1000 kWt 1500 kWt 2000 kWt
1 Boiler 1 200 kWt 300 kWt 500 kWt 750 kWt 1000 kWt 1500 kWt 2000 kWt
2 Boiler circuit pump 1 25 m3 25 m3 28 m3 28 m3 60 m3 60 m3 60 m3
3 Heating circuit pump 1 25 m3 25 m3 50 m3 50 m3 100 m3 110 m3 110 m3
4 Emergency diesel-generator 1 9 kWt 9 kWt 30 kWt 30 kWt 30 kWt 60 kWt 60 kWt
5 Expansion tank 1 80 l 80 l 140 l 140 l 300 l 400 l 400 l
6 Fresh air heating up system Quon 1-1250 m3/h 1-1250 m3/h 1-1700 m3/h 1-1700 m3/h 1-1700 m3/h 1-3500 m3/h 1-3500 m3/h
7 Isolated building of container type 1 1õ20" 1õ20" 1õ20" 1õ40" 1õ40" 1õ40" 1õ40"
8 Boiler flue 1 DN200 DN250 DN300 DN400 DN400 DN500 DN600
9 Burner 1              
10 Water treatment (softening) 2 m3 1              
11 Fresh air heating up pump UPSD 32 1              
12 In-feed pump and CRES-10 system pressure maintenance pump 2              
13 Heat exchanger 90/70 of corresponding capacity 2              
14 Automation unit 1              
15 Reservoir for treated water 2000 l 1              
16 Pipelines, cut-off and safety fittings, electric equipment. Assembled and connected                
 
 

3. Double boiler plant specification

Specification of modular boiler houses 100-2000 kWt with single boiler
¹ Boiler house capacity Quont 200 kWt 400 kWt 600 kWt 1000 kWt 1500 kWt 2000 kWt 3500 kWt 4000 kWt
1 Boiler 2 100 kWt 200 kWt 300 kWt 500 kWt 750 kWt 1000 kWt 1500 kWt 2000 kWt
2 Boiler circuit pump 2 25 m3 25 m3 25 m3 28 m3 28 m3 60 m3 60 m3 60 m3
3 Heating circuit pump 2 25 m3 25 m3 25 m3 50 m3 50 m3 100 m3 110 m3 110 m3
4 Emergency diesel-generator 1 30 kWt 30 kWt 30 kWt 60 kWt 60 kWt 60 kWt 100 kWt 100 kWt
5 Expansion tank 2 80 l 80 l 80 l 140 l 140 l 300 l 400 l 400 l
6 Fresh air heating up system quont 1-1250 m3/h 1-1250 m3/h 1-1250 m3/h 1-1700 m3/h 1-1700 m3/h 1-1700 m3/h 2-3500 m3/h 2-3500 m3/h
7 Isolated building of container type 1 1õ40" 1õ40" 1õ40" 1õ40" 2õ40" 2õ40" 2õ40" 2õ40"
8 Boiler flue 2 DN200 DN200 DN250 DN300 DN400 DN400 DN500 DN600
9 Burner 2                
10 Water treatment (softening) 2 m3 1                
11 Fresh air heating up pump UPSD 32 2                
12 In-feed pump and CRES-10 system pressure maintenance pump 4                
13 Heat exchanger 90/70 of corresponding capacity 2                
14 Automation unit 1                
15 Reservoir for treated water 2000 l 1                
16 Pipelines, cut-off and safety fittings, electric equipment. Assembled and connected.                  
 

4. Normative documents
 
SNiP (construction norms and specifications) 2.04.08-87* “Gas supply”
SNiP 2.04.05-91* “Heating, Ventilation and Air Conditioning”
SNiP 2.08.01-89* “Dwelling Houses”
SNiP II-89-80 General layouts of industrial enterprises
SNiP 2.11.03-93 Storage facilities for oil and oil products. Fire safety norms.
SNiP II-35-76 Boiler plants. Norms of design.
SNiP 11-98* Refueling stations. Fire safety requirements.
SNiP 42-101-2002 Design and construction of gas pipelines made of polyethylene tubes and worn out pipelines reconstruction.
GOST 5542-87 “Combustible natural gases for industrial and public use. Technical specifications”
SR 12-609-03 Safety requirements for objects using liquefied hydrocarbon gases
SR 12-529-03 Safety requirements for systems of gas distribution and gas consumption.
SR 03-576-03 Requirements for safe operation of pressure vessels.
SP 42-101-2003 General Norms of design and construction for gas distributing systems made of metal and polyethylene tubes.