About GAS REGION INVEST
The catalogue of the goods
Our objects
Contacts
Projecting LPG
NEWS

We install business class Boiler rooms based on Vaillant products

Vaillant is modern, efficient and reliable technology for heating your house and hot water needs. The company was founded in 1894 in Germany. Over 130 years of its history the company has won the confidence of the millions of users. All Vaillant products on the Russian market are adapted to the Russian conditions and supported with all the required certificates and licenses.

Vaillant is the part of the Vaillant Group with 10,055 employees. The Vaillant Group Headquarters is located in Remscheid (Germany).

Selling over 2.7 million of heating products and having the turnover ?1.99 billion per year, the Vaillant Group is one of the leading manufacturers in the heating technology market in Europe. The Vaillant Group is also one of the market leaders in such sectors as wall-mounted heating units, floor boilers, water heaters, as well as electric equipment. The Vaillant Group occupies 27% of the market of the wall-mounted heating units. It is the leader in Europe and one of the leading manufactures in this sector around the world. The Vaillant Group products are represented at the heating technology market of more than 100 countries.

atmoVIT (16-56 kW)

Single-stage burner heating boilers.

AtmoVIT boilers are fully automated boilers with integrated single-stage atmospheric gas burner.

The boilers are available in a range of 16 to 56 kW.












Design features:

  • Single-stage low temperature boiler
  • cast iron sectional heat exchanger
  • Pro-E system (plug-in electric connection system)
  • High efficiency up to 92% on an average for a heating period
  • Low NOx emissions less 150 mg/kW.h
  • Electronic ignition and flame monitoring system
  • Conventionally equipped with a built-in inverted draft sensor
  • Electronic monitoring, adjustment and troubleshooting system
  • Colour: white / platinum

 

Installation features:

  • Gas boilers with atmospheric pressure jet burner without a fan for boiler temperature changing mode
  • Possible to use as heat generator in the units providing heating and/or hot water needs (combined with water heater)
  • Possibility to use natural gas as well as liquefied gas (at proper readjustment)

 

Equipped with:

  • Built-in electronic temperature sensor, electronic inverted draft sensor, ignition system, and flame monitoring
  • Single-stage burner with heat-eliminating ceramic rods and automatic gas pressure control
  • Control panel with integrated temperature control of the supply line and the water heater temperature
  • Connection of any Vaillant analogue controls (terminals 7-8-9)
  • Height-adjusted boiler feet
  • Overheat control
  • Spare space for build-in VRC 410s and VRC 420s controllers.
  • Installation and operation guidance in Russian language (in the scope of supply)

 

atmoVIT exclusiv (16-47 kW)

Two-stage burner heating boilers

atmoVIT exclusiv boilers are fully automated boilers with integrated two-stage atmospheric gas burner.

The boilers are available from 16 to 47 kW.

 

 

Design features:

  • Pro-E system (plug-in electric connection system)
  • two-stage technology (two-stage low temperature boiler with lambda control)
  • cast iron sectional heat exchanger with front door for visual control and cleaning
  • High efficiency up to 94% on an average for a heating period
  • Low NOx emissions < 60 mg/kW.h
  • Electronic ignition and flame monitoring system
  • Conventionally equipped with a built-in inverted draft sensor
  • Electroniñ monitoring, adjustment and troubleshooting system
  • Colour: white / platinum

 

Installation features:

  • Gas boilers with atmospheric pressure jet burner without a fan for boiler temperature changing mode
  • Possible to use as heat generator in the units providing heating and/or hot water needs (combined with water heater)
  • Possibility to use natural gas as well as liquefied gas (at proper readjustment)

 

Equipped with:

  • built-in electronic temperature sensor, electronic inverted draft sensor, ignition system, and flame monitoring
  • single-stage burner with heat-eliminating ceramic rods and automatic gas pressure control
  • Control panel with integrated temperature control of the supply line and the water heater temperature
  • Connection of any Vaillant analogue controls (terminals 7-8-9)
  • Height-adjusted boiler feet
  • Overheat control
  • Spare space for build-in VRC 410s and VRC 420s controllers.
  • Installation and operation guidance in Russian language (in the scope of supply)

 

atmoCRAFT

High power heating boilers

atmoCRAFT boilers are fully automated high power boilers with integrated two-stage atmospheric gas burner. The boilers are available from 65 to 160 kW.

 

 

Design features:

  • Pro-E system (plug-in electric connection system)
  • two-stage technology (two-stage low temperature boiler with lambda control)
  • cast iron sectional heat exchanger
  • High efficiency up to 92% on an average for a heating period
  • Low NOx emissions < 150 mg/kW.h
  • Electronic ignition and flame monitoring system
  • Electroniñ monitoring, adjustment and troubleshooting system (DIA-system)
  • Colour: white / grey

 

Installation features: Gas boilers with atmospheric pressure jet burner without a fan for boiler temperature changing mode Possible to use as heat generator in the units providing heating and/or hot water needs (combined with water heater)

Equipped with:

  • Thermal insulation and white powder spraying coating
  • Built-in electronic boiler temperature sensor
  • Electronic inverted draft sensor is supplied as an option
  • Two-stage burner with gradual ignition from a pilot
  • lambda control exhaust gas throttle, i.e. setting the ratio of the combustion air on the first and the second stages
  • Control panel with integrated temperature control of the supply line and the water heater temperature
  • DIA-system monitor with lighting
  • Connection of any Vaillant analogue controls (terminals 7-8-9)
  • Height-adjusted boiler feet
  • Overheat control (1100C)
  • Spare space for build-in VRC 410s and VRC 420s controllers.
  • Installation and operation guidance in Russian language (in the scope of supply)

 

atmo TEC plus VU (24-28 kW)

Heating boilers with natural combustion gas discharge to a chimney

Since June, 2007 Vaillant has been offering you a new generation of wall-mounted atmoTEC boilers, that has replaced atmoMAX boilers.

The atmoTEC plus VU boilers are available of 24 and 28 kW.

 

 

Specifications and features

  • Wall-mounted gas heating unit with integrated domestic water heating
  • The unit power is controlled by modulating burner
  • natural combustion gas discharge to a chimney
  • Automatic switch over to domestic water heating mode at a flow rate 1.5l per minute, and flow rate and heated water temperature control of a unit power
  • Heating and integrated hot water supply
  • For reconstructed and being constructed dwelling houses and apartments
  • Possibility to install in a dwelling area
  • Minimum required side clearance is 20mm, all elements are front accessible
  • Built-in flow-type scale resisting laminar heat exchanger for water heating
  • Built-in circulating pump with automatic stage control, closed expansion tank, automatic air bleeder, automatically adjusted overflow valve, safety valve
  • Intelligent heating system pressure control
  • Primary copper heat exchanger SUPRAL coated with medium efficiency >=91%
  • Built-in flow-type scale resisting laminar heat exchanger for water heating in VUW units
  • chrome-nickel steel burner
  • continuous freezing protection
  • jam protection of the pump and 3-way valve being not operated for more than 24 hours
  • possibility to set at partial power in a heating mode
  • Electronic ignition and functions control
  • Status control and fault monitoring via monitoring system with LCD monitor, lighting and large buttons
  • Connecting assembly in the scope of supply
  • Integrated switchover unit for e-bus interface

 

atmo TEC plus VUW (20-28 kW)

Heating boilers with integrated water heating and natural combustion gas discharge to a chimney

Since June, 2007 Vaillant has been offering you a new generation of wall-mounted atmoTEC boilers, that has replaced atmoMAX boilers.

The atmoTEC plus VUW boilers are available of 20, 24 and 28 kW.

 

 

Specifications and features

  • Wall-mounted gas heating unit
  • The unit power is controlled by modulating burner
  • natural combustion gas discharge to a chimney
  • built-in 3-way selector valve
  • House and water heating combined with storage heater
  • For reconstructed and being constructed dwelling houses and apartments
  • Possibility to install in a dwelling area
  • Minimum required side clearance is 20mm, all elements are front accessible
  • Possible to combine with different types of VIH water heaters for hot water needs
  • Built-in circulating pump with automatic stage control, closed expansion tank, automatic air bleeder, automatically adjusted overflow valve, safety valve
  • Intelligent heating system pressure control
  • Primary copper heat exchanger SUPRAL coated with medium efficiency >=91%
  • chrome-nickel steel burner
  • continuous freezing protection
  • jam protection of the pump and 3-way valve being not operated for more than 24 hours
  • possibility to set at partial power in a heating mode
  • Electronic ignition and functions control
  • Status control and fault monitoring via monitoring system with LCD monitor, lighting and large buttons
  • Connecting assembly in the scope of supply
  • Integrated switchover unit for e-bus interface

 

turbo TEC plus VU (12-28 kW)

Heating boilers with force draft combustion gas discharge to a chimney

Since June, 2007 Vaillant has been offering you a new generation of wall-mounted turboTEC boilers, that have replaced turboMAX boilers.

The turboTEC plus VU boilers are available of 12, 20, 24 and 28 kW.

 

 

Specifications and features

  • Gas Wall-mounted heating unit
  • The unit power is controlled by modulating burner
  • Force draft combustion gas discharge to a chimney
  • House and water heating combined with storage heater
  • For reconstructed and being constructed dwelling houses and apartments
  • Possibility to install in a dwelling area
  • Minimum required side clearance is 5mm, all elements are front accessible
  • Possible to combine with different types of VIH water heaters for hot water needs
  • Possibility to use in dusty rooms as the operation is independent of inside air
  • Built-in circulating pump with automatic stage control, closed expansion tank, automatic air bleeder, automatically adjusted overflow valve, safety valve
  • Built-in priority selector valve with electric actuator
  • Intelligent heating system pressure control
  • Primary copper heat exchanger SUPRAL coated with medium efficiency >=91%
  • chrome-nickel steel burner
  • continuous freezing protection
  • jam protection of the pump and 3-way valve being not operated for more than 24 hours
  • possibility to set at partial power in a heating mode
  • Electronic ignition and functions control
  • Status control and fault monitoring via monitoring system with LCD monitor, lighting and large buttons
  • Connecting assembly in the scope of supply
  • Integrated switchover unit for e-bus interface

 

turbo TEC plus VUW (20-36 kW)

Heating boilers with integrated water heating and force draft combustion gas discharge to a chimney

Since June, 2007 Vaillant has been offering you a new generation of wall-mounted turboTEC boilers, that have replaced turboMAX boilers.

The turboTEC plus VUW boilers are available of 20, 24, 28, 32 and 36kW.

 

 

Specifications and features

  • Wall-mounted gas heating unit with integrated domestic water heating
  • The unit power is controlled by modulating burner
  • Hot water temperature control
  • Automatic switch over to domestic water heating mode at a flow rate 1.5l per minute, and flow rate and heated water temperature control of a unit power
  • Force draft combustion gas discharge to a chimney
  • Heating and integrated hot water supply
  • For reconstructed and being constructed dwelling houses and apartments
  • Possibility to install in a dwelling area
  • Minimum required side clearance is 5mm, all elements are front accessible
  • Built-in flow-type scale resisting laminar heat exchanger for water heating
  • Built-in circulating pump with automatic stage control, closed expansion tank, automatic air bleeder, automatically adjusted overflow valve, safety valve, priority selector valve with electric actuator
  • Intelligent heating system pressure control
  • Primary copper heat exchanger SUPRAL coated with medium efficiency >=91%
  • Built-in flow-type scale resisting laminar heat exchanger for water heating
  • chrome-nickel steel burner
  • continuous freezing protection
  • jam protection of the pump and 3-way valve being not operated for more than 24 hours
  • possibility to set at partial power in a heating mode
  • Electronic ignition and functions control
  • Status control and fault monitoring via monitoring system with LCD monitor, lighting and large buttons
  • Connecting assembly in the scope of supply
  • Integrated switchover unit for e-bus interface

 

atmo TEC pro VUW (24 kW)

Heating boilers with integrated water heating and natural combustion gas discharge to a chimney

Since June, 2007 Vaillant has been offering you a new generation of wall-mounted atmoTEC boilers, that have replaced atmoMAX boilers.

The atmoTEC pro VUW boilers are available of 24 kW.

 

 

Specifications and features

  • Wall-mounted gas heating unit with integrated domestic water heating
  • The unit power is controlled by modulating burner
  • natural combustion gas discharge to a chimney
  • Hot water temperature control
  • Automatic switch over to domestic water heating mode at a flow rate 1.5l per minute,
  • House water Heating combined with a storage heater
  • For reconstructed and being constructed dwelling houses and apartments
  • Possibility to install in a dwelling area
  • Minimum required side clearance is 20mm, all elements are front accessible
  • Built-in flow-type scale resisting laminar heat exchanger for water heating
  • Built-in circulating pump with automatic stage control, closed expansion tank, automatic air bleeder, automatically adjusted overflow valve, safety valve, priority selector valve with electric actuator
  • Intelligent heating system pressure control
  • Primary copper heat exchanger SUPRAL coated with medium efficiency >=91%
  • Built-in storage heater control
  • chrome-nickel steel burner
  • continuous freezing protection
  • jam protection of the pump and 3-way valve being not operated for more than 24 hours
  • possibility to set at partial power in a heating mode
  • Electronic ignition
  • Status control and fault monitoring via monitoring system with LCD monitor
  • Connecting assembly in the scope of supply
  • Integrated switchover unit for e-bus interface

 

turbo TEC pro VUW (24 kW)

Heating boilers with integrated water heating and force draft combustion gas discharge to a chimney

Since June, 2007 Vaillant has been offering you a new generation of wall-mounted turboTEC boilers, that have replaced turboMAX boilers.

The turboTEC pro VUW boilers are available of 24 kW.

 

 

Specifications and features

  • Wall-mounted gas heating unit with integrated domestic water heating
  • The unit power is controlled by modulating burner
  • Force draft combustion gas discharge to a chimney
  • Hot water temperature control
  • Automatic switch over to domestic water heating mode at a flow rate 1.5l per minute
  • Heating and integrated hot water supply
  • For reconstructed and being constructed dwelling houses and apartments
  • Possibility to install in a dwelling area
  • Minimum required side clearance is 5mm, all elements are front accessible
  • Built-in flow-type scale resisting laminar heat exchanger for water heating
  • Built-in circulating pump with automatic stage control, closed expansion tank, automatic air bleeder, automatically adjusted overflow valve, safety valve, priority selector valve with electric actuator
  • Intelligent heating system pressure control
  • Primary copper heat exchanger SUPRAL coated with medium efficiency >=91%
  • chrome-nickel steel burner
  • continuous freezing protection
  • jam protection of the pump and 3-way valve being not operated for more than 24 hours
  • possibility to set at partial power in a heating mode
  • Electronic ignition
  • Status control and fault monitoring via monitoring system with LCD monitor,
  • Connecting assembly in the scope of supply
  • Integrated switchover unit for e-bus interface

 

Homepage | About Gas Region Invest | Our objects | NEWS | Projecting LPG | Contacts