Evaporating plants
Evaporating plants FAS
Evaporating plants convert high pressure propane-butane liquid phase (1-16 bar) into low pressure vapor phase (30-70 mbar), ready to be supplied to a burner. Evaporators are used as a part of Independent Gas Supply system for working with high power consumers, where natural propane-butane evaporation is not sufficient.
Dry evaporator FAS 2000, for propane-butane, Ex-zone 2, cylindrical f orm, indirect heating, electric connection – 3-phase alternative current 400 V/50 Hz. Complies with DIN 30696, TRB 801/25 VDE 0165.
| Models: With 2 electromagnetic valves at evaporator’s inlet; With 1 electromagnetic valve (B). Evaporator has a sealed housing and is meant for using outside dwelling and industrial premises. |
Evaporating plant with evaporator FAS 2000, Ex-zone 2, indirect electric heating, electric connection – 400 V/50 Hz.
| Models: A-output pressure 0,8 bar (32 kg/h and 64 kg/h) or 1,5 bar (100 kg/h); B –with additional low pressure control SAV/SVB 50 mbar. Delivery set: - Steel paint-covered case with vent holes, console 100 mm;
- Ball valve at inlet and outlet, between cutoff and medium pressure control;
- Dirt pocket and safety valve;
- Evaporator;
- Cut off valve with discharge;
- Manometer 0-25 bar with lock valve;
- Medium pressure control SAV/SBV with manometer
Liquid level sensor FTL-50, one channel converter FTL 320, electric control board for installation inside the building and outside dangerous zone and additional pipeline for vapor phase are deliver upon additional request. |
Dry evaporator Power XP, for propane-butane, indirect electric heating, pressure 26 bar, explosion free design NFPA 58/70. Connection to pipelines ¾”, ½” NPT IG
| Evaporator is equipped with: - Electromagnetic valve at inlet;
- Heat control rely
- Safety valve for 17,2 bar.
|
Evaporating plant FAS with XP evaporator, indirect heating, Ex-zone, in steel case.
| Delivery set: - Steel paint covered case with vent holes;
- Ball valve at inlet and outlet, between cutoff and medium pressure control;
- Dirt pocket and safety valve;
- Evaporator XP;
- Cut off valve with discharge;
- Manometer 0-25 bar with lock valve
- Medium pressure control (input pressure 16 bar, output pressure – 1,5 bar);
- Low pressure control (1,5 bar/300mbar).
Liquid level sensor, converter Nivotester (230/50 Hz), additional pipeline for vapor phase are deliver upon additional request. |
Liquid evaporator FAS 3000 indirect water heating. Model – vertical tube evaporator.
| Delivery set: - Double thermostat for gas temperature control;
- Liquid level gage control;
- Electromagnetic valve at liquid phase inlet;
- Safety valve at gas phase;
- Gas and water thermometer;
- Pressure control equipment;
- Ball valves for discharge and relief;
- Remote control board.
|
Direct Fired evaporator doesn’t require hot water and energy supply. It is compact, simple and complies with all requirements of DGRL 97/23/EG norms.
| This device ensures propane-butane evaporation due to work-chamber heating by own burner. Evaporator in enclosed in a metal case and must be installed outside. Its design complies with safety requirements for H module (European Pressure Equipment Directive). |